| POWER |
| |
POWERPRO 25 |
POWERPRO 45 |
POWERPRO 65 |
POWERPRO 100 |
POWERPRO 125 |
POWERPRO 150 |
| Engine Type |
ISUZU AA-4LE1 |
Nissan 2A-BD30T |
Isuzu EE-4BG1T |
Isuzu EE-6BG1T |
Volvo TAD720GE |
Volvo TAD720GE |
| Generator Type |
Taiyo |
Taiyo |
Taiyo |
Taiyo |
Taiyo |
Taiyo |
| Standby Power Rating* |
| Single Phase 120V |
66 amps (L1-N, L3-N at load) |
116 amps (L1-N, L3-N at load) |
161 amps (L1-N, L3-N at laod) |
256 amps (L1-N, L3-N at laod) |
321 amps (L1-N, L3-N at laod) |
396 amps (L1-N, L3-N at load) |
| Single Phase 240V |
66 amps |
116 amps |
161 amps |
256 amps |
321 amps |
396 amps |
| Three Phase 208V |
73 amps |
128 amps |
177 amps |
280 amps |
351 amps |
433 amps |
| Three Phase 480V |
33 amps |
58 amps |
81 amps |
127 amps |
160 amps |
198 amps |
| Prime Power Rating** |
| Single Phase 120V |
60 amps (L1-N, L3-N at load) |
108 amps (L1-N, L3-N at load) |
152 amps (L1-N, L3-N at load) |
242 amps (L1-N, L3-N at load) |
300 amps (L1-N, L3-N at load) |
363 amps (L1-N, L3-N at load) |
| Single Phase 240V |
60 amps |
108 amps |
152 amps |
242 amps |
300 amps |
363 amps |
| Three Phase 208V |
67 amps |
119 amps |
167 amps |
264 amps |
328 amps |
394 amps |
| Three Phase 480V |
30 amps |
54 amps |
76 amps |
120 amps |
150 amps |
180 amps |
| |
| GENERATOR SPECIFICATIONS |
| |
POWERPRO 25 |
POWERPRO 45 |
POWERPRO 65 |
POWERPRO 100 |
POWERPRO 125 |
POWERPRO 150 |
| Voltage - Three Phase |
208, 220, 240, 416, 440, 480V - Switchable |
208, 220, 240, 416, 440, 480V - Switchable |
208, 220, 240, 416, 440, 480V - Switchable |
208, 220, 240, 416, 440, 480V - Switchable |
208, 220, 240, 416, 440, 480V - Switchable |
208, 220, 240, 416, 440, 480V - Switchable |
| Voltage - Single Phase |
120, 127, 139, 240, 254, 277V - Switchable |
120, 127, 139, 240, 254, 277V - Switchable |
120, 127, 139, 240, 254, 277V - Switchable |
120, 127, 139, 240, 254, 277V - Switchable |
120, 127, 139, 240, 254, 277V - Switchable |
120, 127, 139, 240, 254, 277V - Switchable |
| Excitation |
Brushless with AVR |
Brushless with AVR |
Brushless with AVR |
Brushless with AVR |
Brushless with AVR |
Brushless with AVR |
| Voltage Regulation |
0.5% (No Load to Full Load) |
0.5% (No Load to Full Load) |
0.5% (No Load to Full Load) |
0.5% (No Load to Full Load) |
0.5% (No Load to Full Load) |
0.5% (No Load to Full Load) |
| Insulation |
Class F |
Class F |
Class F |
Class F |
Class F |
Class F |
| Power Factor |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
| Frequency |
60 hertz |
60 hertz |
60 hertz |
60 hertz |
60 hertz |
60 hertz |
| Generator RPM |
1,800 rpm |
1,800 rpm |
1,800 rpm |
1,800 rpm |
1,800 rpm |
1,800 rpm |
| Standby Output |
22kW/27.5kVA (Three Phase), 15.8kW/15.8kVA (Single Phase) |
38.8kW/48.5kVA (Three Phase), 28kW/28kVA (Single Phase) |
53.6kW/67kVA (Three Phase), 39kW/39kVA (Single Phase) |
84.8kW/106kVA (Three Phase), 61.5kW/61.5kVA (Single Phase) |
107kW/134kVA (Three Phase), 77kW/77kVA (Single Phase) |
132kW/165kVA (Three Phase), 95kW/95kVA (Single Phase) |
| Prime Output |
20kW/25kVA (Three Phase), 14.4kW/14.4kVA (Single Phase) |
36kW/45kVA (Three Phase), 26kW/26kVA (Single Phase) |
50kW/63kVA (Three Phase), 36.5kW/36.5kVA (Single Phase) |
80kW/100kVA (Three Phase), 58kW/58kVA (Single Phase) |
100kW/125kVA (Three Phase), 72kW/72kVA (Single Phase) |
120kW/150kVA (Three Phase), 87kW/87kVA (Single Phase) |
| Number of Poles |
4 |
4 |
4 |
4 |
4 |
4 |
| Armature Connection |
Star with Neutral/Zig Zag |
Star with Neutral/Zig Zag |
Star with Neutral/Zig Zag |
Star with Neutral/Zig Zag |
Star with Neutral/Zig Zag |
Star with Neutral/Zig Zag |
| |
| ENGINE SPECIFICATIONS |
| |
POWERPRO 25 |
POWERPRO 45 |
POWERPRO 65 |
POWERPRO 100 |
POWERPRO 125 |
POWERPRO 150 |
| Engine Design |
4-Cycle, 4 Cyl., Water-cooled, Swirl Chamber |
4-Cycle, 4 Cyl., Water-Cooled, Direct Injection Turbocharged |
4-Cycle, 4 Cyl., Water-Cooled, Direct Injection Turbocharged |
4-Cycle, 6 Cyl., Water-Cooled, Direct Injection Turbocharged, Air to Air Intercooled |
4-Cycle, 6 Cyl., Water-Cooled, Direct Injection Turbocharged, Air to Air Intercooled |
4-Stroke, 6 Cyl., Water-Cooled, Direct Injection Turbocharged, Air to Air Intercooled |
| Displacement |
133 cu in |
180 cu in |
264 cu in |
396 cu in |
436 cu in |
436 cu in |
| Bore x Stroke |
3.3 x 3.8 in |
3.8 x 4.0 in |
4.1 x 4.9 in |
4.1 x 4.9 in |
4.3 x 5.1 in |
4.3 x 5.1 in |
| Horsepower |
31.5 hp @ rated speed |
58.3 hp @ rated speed |
77.7 hp @ rated speed |
150.2 hp @ rated speed |
190.4 hp @ rated speed |
190.4 hp @ rated speed |
| Fuel Consumption |
1.8 gph @ Full Load
1.2 gph @ 75% Load
1.0 gph @ 50% Load |
2.7 gph @ Full Load
2.0 gph @ 75% Load
1.5 gph @ 50% Load |
4.0 gph @ Full Load
3.0 gph @ 75% Load
2.1 gph @ 50% Load |
5.9 gph @ Full Load
4.7 gph @ 75% Load
3.3 gph @ 50% Load |
6.4 gph @ Full Load
5.1 gph @ 75% Load
3.9 gph @ 50% Load |
8.7 gph @ Full Load
6.5 gph @ 75% Load
4.7 gph @ 50% Load |
| Coolant/Oil Capacity |
1.6/2.1 |
2.9/2.6 |
4/3.7 gal |
6.3/5.3 |
6.7/5.4 |
6.7/5.4 |
| Battery/Starting System |
12V DC/Electric |
12V DC/Electric |
24V DC/Electric |
24V DC/Electric |
12V DC/Electric |
12V DC/Electric |
| |
| WEIGHTS AND DIMENSIONS |
| |
POWERPRO 25 |
POWERPRO 45 |
POWERPRO 65 |
POWERPRO 100 |
POWERPRO 125 |
POWERPRO 150 |
| Overall L x W x H |
67 x 28 x 37 in |
74 x 34 x 48 in |
82 x 34 x 48 in |
106 x 46 x 55 in |
119 x 46 x 58 in |
119 x 46 x 58 in |
| Approx. Net Dry Weight |
1,355 lbs |
2,070 lbs |
2,600 lbs |
3,877 lbs |
4,805 lbs |
5,137 lbs |
| Sound Level – Full Load |
65 dB(A) @ 23 ft |
61 dB(A) @ 23 ft |
64 dB(A) @ 23 ft |
68 dB(A) @ 23 ft |
71 dB(A) @ 23 ft |
71 dB(A) @ 23 ft |
| Skid Fuel Tank Capacity |
17 gal |
26 gal |
36 gal |
59.4 gal |
66 gal |
66 gal |
| Trailer Fuel Tank Capacity |
50 gal |
100 gal |
100 gal |
150 gal |
150 gal |
150 gal |
| |
Generator accessories available as an MMD option on all models: Electronic Governor Control, Battery Charger, Camlock Connectors and Engine Block Heater.
NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
* Standby Power rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS-5514, AS-2789 and DIN-6271.
** Prime Power ratings apply to installations where utility power is not available or is unreliable. A 10% overload capacity is available for 1 hour out of 12.
For additional information on the ratings, please contact MMD Equipment. Manufacturer's design and specification are subject to change without prior notice.
Limited Warranty: 1 year from ship date bumper-to-bumper warranty on entire machine (parts and labor). 2 year unlimited hours on alternator (parts and labor). 5 years, 5,000 hours on engine (Nissan and Isuzu) (parts and labor). |